Horizontal LAF benches
Unidirectional HEPA-filtered air moving across the work surface toward the operator — for product protection where the sample must stay clean and the material is not hazardous.
Imported · Scientora-specified
Our Products
Clean, unidirectional air where the work needs it — with the certification paperwork in place from the day it is installed.
Unidirectional HEPA-filtered air moving across the work surface toward the operator — for product protection where the sample must stay clean and the material is not hazardous.
Imported · Scientora-specified
Downflow HEPA-filtered air over the work zone, for taller assemblies and processes where a horizontal stream would disturb the work.
Imported · Scientora-specified
Class II Type A2 cabinets giving product, operator and environmental protection for microbiological and cell-culture work, with inflow and downflow monitoring.
Imported · Scientora-specified
Small enclosed workstations with HEPA filtration and UV decontamination for nucleic-acid preparation, sized for a bench corner.
Imported · Scientora-specified
Softwall and hardwall modular enclosures where a full cleanroom build is not justified but the process needs controlled air.
Imported · Scientora-specified
Replacement HEPA and pre-filters, UV lamps and gaskets for the units we supply, held for the equipment we have installed.
Imported · Scientora-specified
Specification
| Item | Range / options | Notes |
|---|---|---|
| Nominal width | 900 / 1200 / 1500 / 1800 mm | Bench-top and floor-standing configurations |
| Filtration | HEPA H14 to EN 1822, typically ≥99.995% at MPPS | Pre-filter upstream to extend main filter life |
| Work-zone air cleanliness | ISO Class 5 in the work zone under normal operation | Verified at installation, not assumed |
| Airflow | Unidirectional, horizontal or vertical depending on configuration | Downflow and inflow monitored on Class II units |
| Certification | Performance test and certificate issued at installation | Annual re-certification scheduled and reminded |
| Work surface | 304 stainless steel, coved and seamless | Removable for cleaning underneath |
| Controls | Airflow display, filter-saturation alarm, timed UV where fitted | UV interlocked so it cannot run with the sash open |
They are not interchangeable, and the difference matters for safety. A laminar flow bench protects the product: filtered air moves across the work and out toward the operator. A Class II cabinet protects the product, the operator and the room, because the air leaving the cabinet is filtered too. If there is any biological hazard in the work, the answer is a Class II cabinet, not a LAF bench — and we will say so even when the LAF bench is cheaper.
Every unit we supply is performance-tested and certified at installation, and we put the annual re-certification in a schedule and remind you before it lapses. An expired certificate is one of the fastest ways to fail an inspection.
Request a quote
Attach a floor plan, an equipment list, a mechanical drawing — or even a phone photo of the room as it stands today. Within five business days you'll have a marked-up layout and a budget price. No charge, no obligation.